Hydrogen Water Cooler Gasket Leak
Problem
An original specified reinforced rubber gasket used on the hydrogen water cooler flange leaked while in service.
Solution
Gasket material was upgraded to 1/8” thick Gore Power Grade material (ePTFE). Power Grade material has been proven at numerous plants to be a great choice in hydrogen cooler applications.