Problem
Main Generator Hydrogen coolers typically experience cooling water leaks due to a combination of design which used inexpensive simple rubber gaskets, less than stellar sealing surfaces, lack of adequate bolting and in-service degradation of the sealing surfaces.
Solution
The use of expanded PTFE gasket material such as Gore-Tex Powergrade along with improved bolting procedures has successfully eliminated these leaks at numerous stations.